Paint an impedance profile, drop in parasitics, and watch return loss, insertion loss and ILD respond. Each cell of the profile is a short lossy line, and the S-parameters come from cascading them.
Lengths, positions, stubs and the brush in inches and mil, or millimeters; conductor loss and DC resistance per inch or per centimeter. Saved with the project; the file itself always stores inches.
Tighter spacing and shorter plots, so the TDR, return loss and insertion loss fit on a laptop screen. On by default when the window is less than 900 px tall, except on touch screens. Not saved: the page keeps nothing in your browser.
Tx and Rx, the painted profile, stub impedance and series R go from 1 mΩ (a short) to 1 MΩ (an open), and Rx gets Short and Open buttons. Saved with the project. Turning it off brings values back into the normal ranges; Undo restores them.
ε(f) = ε∞ + Δε·ln((f₂+jf)/(f₁+jf)) / ln(f₂/f₁), anchored to Dk and Df at f_ref. Conductor: R_dc + (1+j)·K·√f.Z = Z_Tx(1+ρ)/(1−ρ). The window sets rise time and ringing; the orange trace is what a TDR would show, the indigo line is the truth.L = 2Z₀∫ρ dt, C = −(2/Z₀)∫ρ dt over round-trip time, with the area computed from the painted profile (exact on a lossless line). Long or large excursions show average impedance and length instead.2√(K·Zin·Zout)/(K−1) and each series resistor Z(K+1)/(K−1) minus it. When Zin ≠ Zout the loss can't go below the minimum-loss pad, 20·log₁₀(√r + √(r−1)) with r the impedance ratio (Johnson and Graham, Advanced Black Magic, Table 5.6; Reference Data for Engineers, ch. 11).